20% OFF shipping at www.animationjamaica.com on orders over $79 + up to 10% OFF products
www.animationjamaica.com
home > PAT Tester PCE-ITE 50 > PAT Tester PCE-ITE 50
download picture
PAT Tester PCE-ITE 50Description Earth Tester Electrical resistance Earthing resistance Loop impedance Voltage measurement Low resistance measurement RCD test The earth tester is a robust earth tester with a large 3. 5" TFT color LCD display. The earth tester also offers, in addition to the various measuring modes such as insulation resistance, grounding resistance, loop impedance, voltage, low impedance measurement and RCD test with the camera function, the possibility
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Description

Earth Tester / Electrical resistance / Earthing resistance /
Loop impedance / Voltage measurement / Low resistance measurement / RCD test

The earth tester is a robust earth tester with a large 3.5" TFT color LCD display. The earth tester also offers, in addition to the various measuring modes such as insulation resistance, grounding resistance, loop impedance, voltage, low-impedance measurement and RCD test with the camera function, the possibility of documenting suitable photos with the measurements. With the earth tester, you can ensure that fixed installations are safely and correctly installed. Thanks to the dual display, the intuitive symbols and the high viewing angle, you can comfortably and quickly perform your measurements with the earth tester. With the low-resistance measurement of the earth tester, you can check grounding conductors, potential equalization rails and protective conductors for low impedance.

The measuring range for low-resistance measurement with the earth tester is in the range of 0 - 2000 Ω with a resolution of 0.001 - 1 Ω. Probably the most important measurement of the earth tester is the measurement of insulation resistance. Electrical cables are placed under voltage during the insulation measurement in order to detect fault currents, Which generate material migration or heat. In most cases, these current faults are so minimal that they are not detected by protective devices and in the worst case they can lead to a fire. The earth tester can carry out installation measurement with a test voltage of 125V, 250V, 500V or 1000V. The load current is in each case 1 mA. The earth tester is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (ground reference or potential reference) and to protect against short-circuit currents and overvoltages, the earthing resistor should be as low-impedance as possible. With a measuring range of 0 ... 2000 Ω with a resolution of 0.01 ... 1 Ω, the earth tester offers all the prerequisites for a meaningful measurement of the grounding resistance.


Highlights

- 3.5" color TFT LCD display
- Loop resistance L-N, L-PE and N-PE
- Adjustable FI test current
- SD card and Bluetooth
- Dual display
- Good / bad FI test
- Low Ohm measurement
- Up to 1000V terminal voltage

Specification

Isolation test

Terminal voltage

Measuring range

Resolution

Accuracy

Load current

Short circuit current

125V (0 ... 10 %)

0,125 ... 4 MΩ

0.001 MΩ

± (2% + 10 digits)

1-mA @ Last 125 kΩ

<= 1-mA

4,001 ... 40 MΩ

0.01 MΩ

± (2% + 10 digits)

40,01 ... 400 MΩ

0.1 MΩ

± (4% + 5 digits)

400,1 ... 1000 MΩ

1 MΩ

± (5% + 5 digits)

250V (0 ... 10 %)

0,125 ... 4 MΩ

0.001 MΩ

± (2% + 10 digits)

1-mA @ Last 250 kΩ

<= 1-mA

4,001 ... 40 MΩ

0.01 MΩ

± (2% + 10 digits)

40,01 ... 400 MΩ

0.1 MΩ

± (3% + 2 digits)

400,1 ... 1000 MΩ

1 MΩ

± (3% + 2 digits)

500V (0 ... 10 %)

0,125 ... 4 MΩ

0.001 MΩ

± (2% + 10 digits)

1-mA @ Last 500 kΩ

<= 1-mA

4,001 ... 40 MΩ

0.01 MΩ

± (2% + 10 digits)

40,01 ... 400 MΩ

0.1 MΩ

± (3% + 2 digits)

400,1 ... 1000 MΩ

1 MΩ

± (4% + 5 digits)

1000 V (0 ... 10 %)

0,125 ... 4 MΩ

0.001 MΩ

± (3% + 10 digits)

1-mA @ Last 1 MΩ

<= 1-mA

4,001 ... 40 MΩ

0.01 MΩ

± (2% + 10 digits)

40,01 ... 400 MΩ

0.1 MΩ

± (3% + 2 digits)

400,1 ... 1000 MΩ

1 MΩ

± (4% + 5 digits)

Low Ohm

Measuring range

Resolution

Accuracy

Max. open circuit voltage

Overload protection

2,000 Ω

0.001 Ω

± (1.5% + 30 digits)

5.8V

250 Vrms

20,00 Ω

0.01 Ω

± (1.5% + 3 digits)

5.8V

250 Vrms

200,0 Ω

0.1 Ω

± (1.5% + 3 digits)

5.8V

250 Vrms

2000 Ω

1 Ω

± (1.5% + 5 digits)

5.8V

250 Vrms

Continuity tester

Measuring range

Resolution

Max. open circuit voltage

Overload protection

Short circuit current

2000 Ω

0.01 Ω

5.8V

250 Vrms

>= 200-mA

Grinding resistance

L-PE (Hi-Amp): Load current 4.0 A

Measuring range

Resolution

Accuracy

0.23 ... 9.99 Ω

0.01 Ω

± (4% + 4 digits)

10.0 ... 99.9 Ω

0.1 Ω

± (4% + 4 digits)

100 ... 999 Ω

1 Ω

± (4% + 4 digits)

L-PE (without tripping): Load current 15-mA

Measuring range

Resolution

Accuracy

0.23 ... 9.99 Ω

0.01 Ω

± (5% + 6 digits)

10.0 ... 99.9 Ω

0.1 Ω

± (5% + 6 digits)

100 ... 999 Ω

1 Ω

± (5% + 6 digits)

L-N: Load current 4.0 A

Measuring range

Resolution

Accuracy

0.23 ... 9.99 Ω

0.01 Ω

± (4% + 4 digits)

10.0 ... 99.9 Ω

0.1 Ω

± (4% + 4 digits)

100 ... 999 Ω

1 Ω

± (4% + 4 digits)

RCD Test

RCD (In)

10-mA, 30-mA, 100-mA, 300-mA, 650-mA, 1 A

Factors

x 1/2, x1, x2, x5

Accuracy of the tripping time

± (1% + 1 ms)

Signal form of the test current

Sine (AC)

Tripping characteristics

G and S

Release time

0° or 180°

Voltage range

194 ... 260V AC (50/60 Hz)

Accuracy of current measurement

± (5% + 2 digits)

RCD Types Type A, Type B

Voltage measurement

Measuring range

Resolution

Accuracy

80...500 V AC/DC

1 V

± (2 % + 2 digits)

Frequency measurement

Measuring range

Resolution

Accuracy

45...65 Hz

1 Hz

±2 Hz

Grounding measurement

Measuring range

Resolution

Accuracy

0.00...99.99 Ω

0.01 Ω

± (2% + 30 digits)

100.0...999.9 Ω

0.1 Ω

± (2% + 6 digits)

1000...2000 Ω

1 Ω

± (2% + 6 digits)

General specifications

Power supply

8 x 1.2 ... 1.5V AA batteries

Operating time

ca. 15 h

Measurement category

CAT III 600V

Protection class

IP 65

Display

3.5" TFT (320 x 240 Pixel)

Operating environment

0 ... 45°C
0 ... 95% rH, non condensing

Measurements

24.2 x 10.5 x 14.5 cm

Weight

1.56 kg / 3.4 lbs


Delivery Scope

1 x Earth Tester PCE-ITE 50
1 x User manual

Downloads

PAT Tester PCE-ITE 50

Item no : 56692073941
sold recently : Login >>
US$ 1350.00
Pay in 4 interest-free payments of $337.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 23 - Jun 28

Enjoy 20% off shipping

US$ 1350.00

1-11

US$ 1215.00

12-35

US$ 945.00

36-59

US$ 810.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches